AGM Electrical Supplies Pty Ltd

3/52-54 Parramatta Road
Croydon NSW 2132 (CNR Acton St)

(02) 9745 1302

China Office: +86 21 8036 5437

NZ Customers: +64 9950 8702

*ALL PRICING ON WEBSITE IS INCLUSIVE OF GST.
CALL / EMAIL US FOR PRICING ON PROJECTS*

SHOWROOM OPEN 7 DAYS

MON - FRIDAY: 6.30AM to 6:00PM
SATURDAY: 7:00AM to 5:00PM
SUNDAY: 10:00AM to 5:00PM
(CLOSED ON PUBLIC HOLIDAYS)

 

Products

3kA 20 Amp Single Pole Safety Switch RCBO RCDMCB 30mA - DL Branded 3 YEARS WARRANTY!

List price: AUD$13.00
AUD$9.90 (Inc 10% GST)
You save: AUD$3.10 (24%)
DRNL-32, RCBO320
In stock
+

3kA 20 Amp Single Pole Safety Switch RCBO RCDMCB 30mA - DL Branded 3 YEARS WARRANTY!

DENROM ELECTRIC ON YOUTUBE (CHINESE MANDARIN)

QTY = 1 PC , BOX QTY = 12 PCS, CARTON QTY = 144 PCS

* ON SPECIAL @ $9+GST EACH ($9.90 INC GST EACH - NO FURTHER DISCOUNTS)

Type: 20 AMP, Single Pole (1P +N), Single Module 18mm Wide

Short Circuit Capacity/Trip Rating: 3kA or 3000A (Suitable For Domestic Applications)

Rated Residual Current: 30mA

RCBO Type: AC Curve

Extremely Safe: It Cut Neutral, Some Major Brand(s) Dont! So you can use

On Temporary or on the Marina

Two Pole Safety Feature: Allows Switching of Both Active & Neutral Contacts

Single Module: Ideal in Saving valuable switchboard space

Australian : SAA131351EA / RCM: N5667 (SEE Attachments Tab For Approval Certificate)

FACTORY DIRECT PRICING

3 Years Replacement Factory

Technical Data

DRNL-32

Standards

AS/NZS 61009 - 1

Magnetic tripping characteristics

B C

Residual tripping characteristics

AC

Rated current

6 - 32

Rated residual current

30 mA

Calibration temperature

30

Rated voltage 1P

240V

Frequency

50/60

Maximum service voltage

264

Tripping Duration:

Instaneous<0.1s

Power supply

Line & Load

Selectivity class

3

Residual making and breaking capacity

2000A

Short circuit capacity

3000A

Isolation application (IEC 60947-2)

Yes

Insulation resistance (Mohm)

1,000

Insulation voltage (V)

500

Dielectric rigidity (V)

2,500

Vibration resistance

1.5g

Endurance (operations) electrical

>6,000

Mechanical

>20,000

Protection degree outside

IP20

inside enclosure

IP40

Self extinguishing degree (UL 94)

V2

Tropicalisation (IEC 60068-2)

+55 /95% RH

Operating temperature

-5/+55

Storage temperature

-25/+70

Terminal capacity (top & bottom) min / max

1-16mm

Terminal torque (top / bottom)

3

Busbar systems

No

Accessories

No

Dimensions (mm)

71(H)81(L)18(W)

Weight (g)

85

Installation Diagram

 

Overall Dimensions

 

DENROM DRNL-32 3kA RCBO

DL DRNL-32 3kA RCBO

DENROM DL7NL-40 6kA RCBO Non Polarised

DL DL7NL-40 6kA RCBO Non Polarised

 

 

ATTN VICTORIAN CUSTOMERS - Please See Attachments Tab For Additional Testing Requirements By ESV Energy Safe Victoria - We have had Additional Testing Done by TUV Rheinland Victoria to show our RCBO's meet the new standards as required By ESV & Additional requirements test reports attached (IN ATTACHMENTS TAB) - Do Not Purchase Any RCBO's that Do Not Meet the new ESV Requirements as it is illegal to sell & use in VICTORIA! Electricians Beware!

PLEASE CHECK THE ESV WEBSITE, DL IS ON THE APPROVED LIST OF RCBO MANUFACTURERS

http://www.esv.vic.gov.au/technical-information/electrical-appliances-and-equipment/list-of-approved-rcbos/


ESV Notice 1 (ESV_Advert_ProhibitionNotice_RCBO.pdf, 418 Kb) [Download]

ESV Notice 2 (ESV_Alert_RCBOs_testing.pdf, 91 Kb) [Download]

TUV 3kA VIC TEST REPORT (50083833.001_DRNL-32_3KA.pdf, 199 Kb) [Download]