Type: 10 AMP, Single Pole (1P +N), Single Module 18mm Wide
Short Circuit Capacity/Trip Rating: Genuine 6kA or 6000A Trip Rating (Suites Commercial Applications)
Rated Residual Current: 30mA
RCBO Type: TYPE A NEW MODEL FROM MAY 1 2023
AS/NZS Australian Standard Tested & Certified & ESV Listed
Two Pole Safety Feature: Allows Switching of Both Active & Neutral Contacts
Single Module: Ideal in Saving valuable switchboard space
NON POLARISED: Load can enter top or bottom
*FACTORY DIRECT PRICING
*3 Years Replacement Factory Warranty
Technical Data |
DRNL-40 |
Standards |
AS/NZS 61009 - 1 |
Magnetic tripping characteristics |
B ,C |
Residual tripping characteristics |
A |
Rated current |
6, 10, 16, 25, 32, 40 |
Rated residual current |
30 mA |
Calibration temperature |
30 ℃ |
Rated voltage 1P |
240V |
Frequency |
50/60 |
Maximum service voltage |
264 |
Tripping Duration: |
Instaneous<0.1s |
Power supply/LOAD |
TOP OR BOTTOM NON POLARISED! |
Selectivity class |
3 |
Residual making and breaking capacity |
2000A |
Short circuit capacity |
6000A |
Isolation application (IEC 60947-2) |
Yes |
Insulation resistance (Mohm) |
1,000 |
Insulation voltage (V) |
500 |
Dielectric rigidity (V) |
2,500 |
Vibration resistance |
1.5g |
Endurance (operations) electrical |
>6,000 |
Mechanical |
>20,000 |
Protection degree outside |
IP20 |
inside enclosure |
IP40 |
Self extinguishing degree (UL 94) |
V2 |
Tropicalisation (IEC 60068-2) |
+55 ℃/95% RH |
Operating temperature |
-5/+55 ℃ |
Storage temperature |
-25/+70 ℃ |
Terminal capacity (top & bottom) min / max |
1-16mm |
Terminal torque (top / bottom) |
3 |
Busbar systems |
Yes |
Accessories |
No |
Dimensions (mm) |
72(H)81(L)18(W) |
Weight (g) |
105 |
DENROM DRNL-32 3kA RCBO
DL DRNL-32 3kA RCBO
DENROM DL7NL-40 6kA RCBO Non Polarised
DL DL7NL-40 6kA RCBO Non Polarised
ATTN VICTORIAN CUSTOMERS - Please See Attachments Tab For Additional Testing Requirements By ESV Energy Safe Victoria - We have had Additional Testing Done by TUV Rheinland Victoria to show our RCBO's meet the new standards as required By ESV & Additional requirements test reports attached (IN ATTACHMENTS TAB) - Do Not Purchase Any RCBO's that Do Not Meet the new ESV Requirements as it is illegal to sell & use in VICTORIA! Electricians Beware!